    Operation and display General function
    This energy-saving controller for radiators can be used
    to control room temperature on the basis of time. The
    actuator moves a valve, thereby allowing the amount of
    heat flowing to the heating appliance to be controlled. The
    controller is compatible with all standard heating appli-
    ance valves. The large illuminated display ensures user-
    friendly operation.
    Installation can be achieved in 3 easy steps.
    Step 1: Inserting (replacing) the batteries
    Remove the battery compartment cover.•
    Insert 2 new Mignon batteries (LR6/AA) •
    into the side battery compartments, en-
    suring they are the right way round.
    Reattach the battery compartment cover •
    and click into place.
    New alkaline batteries have a life of ap-
    proximately three years. A battery symbol
    (
    ) will indicate when the batteries need to be replaced.
    After removing the old batteries, please wait approximately
    1 minute before inserting the new ones.
    Never recharge standard batteries.
    Doing so will present a risk of explosion.
    Do not throw the batteries into a fire.
    Do not short-circuit batteries.
    Used batteries should not be disposed
    of with regular domestic waste. Instead,
    they should be taken to your local battery
    disposal point.
    Step 2: Setting the date and time of day
    The firmware version number will be displayed briefly once
    you have inserted/replaced the batteries and then you will be
    automatically prompted to set the date and time of day.
    Use the setting wheel (C) to set •
    the year (B).
    Confirm with OK (D).•
    Use the setting wheel (C) to set •
    the month (B).
    Confirm with OK (D).•
    Use the setting wheel (C) to set •
    the day (B).
    Confirm with OK (D).•
    Use the setting wheel (C) to set •
    the hour (A).
    Confirm with OK (D).•
    Use the setting wheel (C) to set the minute (A).•
    Confirm with OK (D).•
    The motor will start moving back the control pin while the
    entries are still being made.
    If “InS” is displayed with a rotating •
    symbol, this
    indicates that the motor is still moving back. Once the
    device is ready for the actuator to be installed on the
    valve, just “InS” will appear on the display.
    The weekly program and other settings can be cus-•
    tomised prior to installation. To do this, press the menu
    button when “InS” is shown on the display. For further
    details, please see “4. Configuration menu”.
    O n c e p r o g r a m m i n g i s c o m p l e t e , “ I n S ” w i l l r e a p p e a r o n t h e •
    display and installation (Step 3) can commence.
    Step 3: Installing the energy-saving controller
    The actuator can be installed on all standard heating
    valves. There is no need to drain away water or fiddle
    around with the heating system before doing this. First,
    you need to remove the old thermostat dial:
    Turn the thermostat dial anti- •
    clockwise as far as it will go (A).
    Release the thermal ring of the •
    thermostat (B).
    Remove the thermostat from •
    the valve (C).
    An adapter will need to be used in
    the case of certain valves. Adapt-
    ers for Danfoss valves (RA, RAV,
    RAVL) are included in the scope of delivery. For details,
    please refer to the adapter overview (see 18).
    The adapter must be placed on the valve •
    and turned until it is secure-
    ly seated.
    In the case of the RAV adapter, •
    the extension supplied must be
    attached to the valve tappet.
    The RA and RAV adapters must, •
    in addition, be secured by means
    of the bolt and nut supplied.
    The energy-saving controller can
    only be installed if “InS” is show-
    ing on the display. Following installation, the actuator will
    perform an adjustment run so that it can adapt to the valve.
    During this process, “AdA” will be displayed.
    Place the actuator on the valve.•
    Tighten the union nut.•
    “InS” will appear on the display, press the OK button.•
    The actuator will perform an adjustment run (“AdA” will •
    appear on the display, operation not possible).
    After that, the actuator will be ready for operation (Auto •
    mode).
    If the adjustment run was initiated prior to installa-
    tion, or if an error message will be displayed (F1, F2,
    F3); press OK to move the motor back to the “InS
    position.
    1. Setting the weekly program
    The weekly program allows you to set up to 3 separate
    heating periods (7 switching times) for each day of the
    week. Programming is performed in relation to the se-
    lected days, for which temperatures must be stored for a
    period from 00:00 to 23:59.
    Press and hold down the menu •
    button for more than 3 seconds.
    “Pro” will appear on the display.•
    Confirm with OK.•
    “dAy” will appear on the display. •
    The setting wheel can be used
    to select an individual day of the
    week, all working days, the weekend or the entire week
    (example shows working days selected).
    Confirm with OK.•
    Use the setting wheel to set the first time segment (exam-•
    ple shows 0:00 to 6:00).
    Confirm with OK.•
    Then, select the required temperature for the selected time •
    segment (example shows 17.0°C).
    Confirm with OK.•
    Keep repeating this process until you have nished storing •
    temperatures for the period from 0:00 to 23:59.
    In Auto mode, the temperature can be modified at any time
    via the setting wheel. The modified temperature will then
    be retained until the next program changeover.
    2. Weekly program: Examples
    The energy-saving controller allows you to store up to 3
    heating periods (7 switching times) with individual temper-
    ature settings for each day of the week. The factory set-
    ting consists of two heating phases (from 6:00 until 9:00
    and from 17:00 until 23:00 respectively) for every single
    day of the week:
    From 00:00 to 06:00 17.0°C
    From 06:00 to 09:00 21.0°C
    From 09:00 to 17:00 17.0°C
    From 17:00 to 23:00 21.0°C
    From 23:00 to 23:59 17.0°C
    To represent the switching periods, the display shows
    bars for every other switching interval. In this exam-
    ple, no bars are shown for the interval from 0:00 to
    6:00. Bars are only shown on the display for the in-
    tervals from 6:00 to 9:00 and from 17:00 to 23:00.
    If a room also needs to be heated at around noon, the cor-
    responding program might look like this:
    Monday to Sunday
    From 00:00 to 06:00 16.0°C
    From 06:00 to 09:00 22.0°C
    From 09:00 to 12:00 17.0°C
    From 12:00 to 14:00 20.0°C
    From 14:00 to 17:30 17.0°C
    From 17:30 to 23:30 21.0°C
    From 23:30 to 23:59 16.0°C
    If you have a home office and only want it to be heated
    during the day on working days, you can program the fol-
    lowing times:
    Monday to Friday
    From 00:00 to 08:30 17.0°C
    From 08:30 to 17:00 21.0°C
    From 17:00 to 23:59 17.0°C
    Saturday and Sunday
    From 00:00 to 23:59 15.0°C
    3. Operating modes
    To switch between the 3 operating modes de scribed below,
    press the menu button briefly (these operating modes can
    only be selected following installation/Step 3):
    Holiday function• ( ) : Set a temperature that is to be
    maintained until a fixed point in time.
    Manu: • Manual operation The temperature is set manu-
    ally using the setting wheel.
    Auto: • W e e k l y p r o g r a m – T h e t e m p e r a t u r e i s c o n t r o l l e d a u t o -
    matically in accordance with the stored weekly program.
    4. Configuration menu
    The configuration menu can be used to modify settings.
    To access this menu, press and hold down the menu
    button (for more than 3 seconds).
    Pro: For setting the weekly program (see Section “1 Set-•
    ting the weekly program”)
    dAt: For modifying the time of day and date•
    POS: For querying the actuator’s current position•
    dSt: Automatic switchover at the start or end of daylight •
    saving time can be deactivated.
    AEr: For setting the “window open” temperature and •
    time so that the temperature is automatically reduced
    in the event of ventilation
    tOF: For setting the offset temperature•
    rES: For restoring the factory settings•
    Please read this manual carefully in order to help you put
    the device into operation. Keep the manual handy so you
    can refer to it at a later date!
    A Day of the week
    B Holiday function (
    ), manual operation (Manu), au-
    tomatic operation (Auto), battery empty” symbol
    (
    ), set-back/comfort temperature ( ), window
    open” symbol (
    )
    C Menu button: Press and hold down the button for more
    than 3 seconds to open the configuration menu
    D Setting wheel: For making adjustments (e.g. temperature)
    E Time and date indicator, menu items, functions
    F Current temperature setting
    G Switching periods set within weekly program
    H OK button: For confirming/saving
    I
    button: For switching between set-back and com-
    fort temperatures
    5
    2
    6
    3
    7
    4
    8
    A
    C
    B
    D
Technoline TM 3010

Χρειάζεστε βοήθεια?

Αριθμός ερωτήσεων: 0

Έχετε κάποια ερώτηση σχετικά με το Technoline TM 3010 ή χρειάζεστε βοήθεια; Κάντε την ερώτησή σας εδώ. Δώστε μια σαφή και περιεκτική περιγραφή του ζητήματος και της ερώτησής σας. Όσο περισσότερες λεπτομέρειες παρέχετε για το ζήτημα και την ερώτησή σας, τόσο πιο εύκολο θα είναι για άλλους αγοραστές του Technoline TM 3010 να απαντήσουν σωστά στην ερώτησή σας.

Δείτε το εγχειρίδιο για το Technoline TM 3010 εδώ, δωρεάν. Αυτό το εγχειρίδιο ανήκει στην κατηγορία Θερμοστάτες και έχει βαθμολογηθεί από 1 άτομα με μέσο όρο 9.3. Αυτό το εγχειρίδιο διατίθεται στις ακόλουθες γλώσσες: Engels. Έχετε κάποια ερώτηση σχετικά με το Technoline TM 3010 ή χρειάζεστε βοήθεια; Κάντε την ερώτησή σας εδώ

Technoline TM 3010 προδιαγραφές

Γενικά
Μάρκα Technoline
Μοντέλο TM 3010
Προϊόν Θερμοστάτης
EAN 4029665130101, 4030152077922
Γλώσσα Engels
Τύπος αρχείου PDF
Χαρακτηριστικά
Λειτουργία μνήμης Όχι
Χρώμα προϊόντος Λευκός (Άσπρος)
Περιβαλλοντικές συνθήκες
Εύρος θερμοκρασίας (Τ - Τ) 8 - 28 °C
Οθόνη
Τύπος οθόνης LCD
Διαχείρηση ενέργειας
Κατανάλωση ρεύματος 100 mA
Τάση μπαταρίας 3 V
Τύπος μπαταρίας AA LR06
Αριθμός υποστηριζόμενων μπαταριών 2
Περιεχόμενο πακέτου
Απομακρυσμένος έλεγχος Όχι
Βάρος και διαστάσεις
Ύψος 99 mm
Βάθος 98 mm
Πλάτος 56 mm

οδηγοσ-χρησησ.gr

Ψάχνετε για ένα εγχειρίδιο; Το οδηγοσ-χρησησ.gr διασφαλίζει ότι θα βρείτε το εγχειρίδιο που ψάχνετε σε χρόνο μηδέν. Η βάση δεδομένων μας περιέχει περισσότερα από 1 εκατομμύριο εγχειρίδια σε μορφή PDF από πάνω από 10.000 μάρκες. Κάθε μέρα προσθέτουμε τα πιο πρόσφατα εγχειρίδια, ώστε να βρίσκετε πάντα το προϊόν που ψάχνετε. Είναι πολύ απλό: απλά πληκτρολογήστε τη μάρκα και τον τύπο του προϊόντος στη γραμμή αναζήτησης και μπορείτε άμεσα να κάνετε δωρεάν online προβολή του εγχειριδίου της επιλογής σας.

οδηγοσ-χρησησ.gr

© Copyright 2021 οδηγοσ-χρησησ.gr Όλα τα Δικαιώματα Παρακρατούνται.

Χρησιμοποιούμε τα cookies για να διασφαλίσουμε ότι θα σας δώσουμε την καλύτερη εμπειρία στην ιστοσελίδα μας. Εάν συνεχίσετε να χρησιμοποιείτε αυτό το site, θα υποθέσουμε ότι συμφωνείτε με αυτό.

Περισσοτερα